PA microwaveValve & Flow Master
 PA microwaveValve & Flow Master
Share this:

PA microwaveValve & Flow Master  PA microwaveValve & Flow Master

Flow rate control valve for non-ferrous and ferrous media for peening and blasting machines

Quantity:
  • Product Description

1. PA microwaveValve

Type Product Number Price
PA μWValve-15: Range 1.5-15 kg/min (ferrous) 822 209 Contact Us
PA μWValve-07: Range 0.7-7 kg/min (non-ferrous) 822 210 Contact Us
PA μWValve-100: Range 10-100 kg/min (ferrous) 822 211 Contact Us
PA μWValve-40: Range 4-40 kg/min (non-ferrous) 822 212 Contact Us

• ±5% full-scale accuracy
• FPGA technology, closed loop in real-time
• Shock resistant Touchscreen for improved troubleshooting
• Meets SAE AMS 2430 and AMS 2432 specifications
• Digital signal: no data transmission lost
• Only one cable per valve
• Able to include 4 media calibrations in one valve
• Includes a 5 meter wire (optional: 1m)
• 24V DC
• CE compliant
• Patented in USA and China

Power 24 Vdc @ 4A (100 VA)
Media Ferrous media and Non-ferrous media
Maximum pressure 6 bar (100 PSI)
Mode Manual/Auto
Temperature range 5°- 48°C(40°-110°F)
Analog input 0 - 10 Vdc
Valve ON signal supply 24 Vdc
Flow sensor output 0 - 10 Vdc

 

2. PA FlowMaster - Media Flow Controller

Special Features:
• Cost savings: One control handles up to four valves!
• 7” touchscreen: reduces hardware button damage;
  flexible on design.
• Six languages as standard configuration: English, French,
  German, Spanish, Japanese and Chinese. Additional
  languages on request.
• Up to 64 recipes that can contain flow rate and product
  name
• Instant adjustments to up to four different shot sizes
  (optional)
• Instant switch from kg/min to lb/min or vice versa
• Alarm - if connection lost to valve
• Adjustable alarm supervision delay for starting the process

Standard Features:
• Displays product info: flow rate, valve status, configuration, alarm, settings, recipes
• Alarm system: flow rate upper/lower limit, connection lost
• Closed loop system, with FPGA technology, closed loop in real-time
• Remote commands and recorder output
• Digital I/O and analog signal card
• CE compliant
• Patented in USA and Europe

Power 24 Vdc @ 0.5A
Analog input 0 - 10 Vdc
Flow recording output 0 - 10 Vdc
Flow enable output 24 Vdc @ 10 mA
Temperature range 32 – 122 ° F (0 – 50 ° C)
Dimensions 188mm (W) x 143mm (H) x 90mm (D)